WickRight Passive Ventilation Products

Clay Coping Vent

00005
$12.00
In stock
1
Product Details

Sold in 4' lengths.
For use under Clay Copings on masonry walls - block, brick or combination.

REQUIREMENT: Installation of WickRight Membrane is required when installing under clay coping tiles.

How to Order:
Measure length of walls, add 10%. Example: Perimeter 180 feet. Order 200 feet.

Instructions for installation under clay copings:

1. Install WickRight Clay Coping Vent open side down. Place the vent length-wise in the middle of the wall - equidistant from the exterior and interior edges of the wall.

2. Install Wickright Vapor Permeable Membrane on top of vent.
Purchase Membrane width that will cover the entire wall
plus 1" – attach membrane to wall near outside edges with thin bead of caulk. Allow Membrane to drape over the side of the wall approx 1/2".